SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

WFRF:(Yang Yong jian)
 

Search: WFRF:(Yang Yong jian) > Wang Kai > Zhang Yong > Integrated assessme...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Integrated assessment of indoor and outdoor ventilation in street canyons with naturally-ventilated buildings by various ventilation indexes

Yang, Xia (author)
Sun Yat-sen University, Guangzhou, PR China
Zhang, Yong (author)
Sun Yat-sen University, Guangzhou, PR China
Hang, Jian (author)
Sun Yat-sen University, Guangzhou, PR China
show more...
Lin, Yuanyuan (author)
Sun Yat-sen University, Guangzhou, PR China
Mattsson, Magnus, 1964- (author)
Högskolan i Gävle,Energisystem och byggnadsteknik,Indoor environment
Sandberg, Mats, 1945- (author)
Högskolan i Gävle,Energisystem och byggnadsteknik,Indoor environment
Zhang, Ming (author)
State Power Environmental Protection Research Institute, Nanjing, China
Wang, Kai (author)
Department of Civil, Environmental and Geomatic Engineering, University College, London, UK
show less...
 (creator_code:org_t)
Elsevier, 2020
2020
English.
In: Building and Environment. - : Elsevier. - 0360-1323 .- 1873-684X. ; 169
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The integrated assessments of indoor and outdoor ventilation are still rare so far. As a novelty, this paper aims to quantify the influence of street aspect ratios (building height/street width, H/W = 0.5–5) and window sizes (1 m × 1 m, 1.5 m × 1.5 m) on indoor-outdoor ventilation in two-dimensional streets with single-sided naturally-ventilated buildings. Numerical simulations with RNG k-ε model are validated against experimental data and the grid independence are tested as well. Air change rates per hour (ACH, h−1) are adopted for assessing indoor-outdoor ventilation by mean flows (ACHmean) and turbulent fluctuations (ACHturb) respectively. Age of air(τ), purging flow rate (PFR) and its corresponding ACHPFR are used to evaluate overall ventilation capacities.Shallower streets experience better indoor-outdoor ventilation. Outdoor ACHPFR drop from 14.69 to 17.55 h−1 to 3.96–3.97 h−1 as H/W rises from 0.5 to 3. In extremely deep canyon (H/W = 5), two-counter-rotating vortices produce much smaller velocity at low-level regions (U/Uref~10−3-10−5), resulting in small ACHPFR for outdoor (~0.76–0.91 h−1) and indoor in 1–13th floors (~0.03–0.61 h−1). When H/W = 0.5–1, leeward 5–6th floors experience smaller ACHPFR(e.g.~1.13–1.40 h−1 as H/W = 1) than the other floors (e.g. ~1.54–9.52 h−1 as H/W = 1). Particularly, as H/W = 2–3, leeward-side indoor ACHPFR in the middle floors (except the first and top two floors) are nearly constants (~1.02–1.69 h−1) and much smaller than windward-side ACHPFR(~1.41–4.35 h−1) which increase toward upper floors. Besides, the smaller window size reduces indoor ACHPFR by 19.38%~88.28%, but hardly influences outdoor ventilation. Moreover, both outdoor and indoor ACHPFR are greater than ACHmean but smaller than ACHmean + ACHturb. Although further investigations are still required, this paper provides an insight and scientific foundation on integrated indoor-outdoor ventilation evaluation with various effective ventilation indexes.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Keyword

Computational fluid dynamics (CFD)
Urban ventilation
Building natural ventilation
Air change rate per hour (ACH)
Age of air
Purging flow rate (PFR)
Hållbar stadsutveckling
Sustainable Urban Development

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view